CLP270M
OVERVOLTAGE AND OVERCURRENT PROTECTION FOR TELECOM LINE
PRELIMINARY DATASHEET
Application Specific Discretes A.S.D.
MAIN APPLICATIONS
Any telecom equipment submitted to transient overvoltages and lightning strikes such as : Analog and ISDN line cards PABX Main Distribution Frames Primary protection modules
s s s s
DESCRIPTION The CLP270M is designed to protect telecommunication equipment. It provides both a transient overvoltage protection and an overcurrent protection. It is housed in a PowerSO-10TM package. FEATURES
s s
PowerSO-10TM
SCHEMATIC DIAGRAM
FS TIP S TIP L TIP L TIP L
1
NC RING S RING L RING L RING L
s
s
s
DUAL BIDIRECTIONAL PROTECTION DEVICE. HIGH PEAK PULSE CURRENT : Ipp = 100A (10/1000 s SURGE) Ipp = 500A (2/10 s SURGE) MAX. VOLTAGE AT SWITCHING-ON : 380V MIN. CURRENT AT SWITCHING-OFF : 150mA FAILURE STATUS OUTPUT PIN
TAB is connected to GND
BENEFITS
s
s
s
s
Both primary and secondary protection levels in one device. Voltage and current controlled suppression. Surface Mounting with PowerSO-10TM package. Line card cost reduction thanks to the very low power rating of external components required : balanced resistors, ring relay, low voltage SLIC protection.
July 2003 - Ed: 7C
1/24
CLP270M
COMPLIES WITH THE FOLLOWING STANDARDS: ITU K20 VDE0433 VDE0878 IEC61000-4-5 FCC Part 68, lightning surge type A FCC Part 68, lightning surge type B BELLCORE TR-NWT-001089 First level BELLCORE TR-NWT-001089 Second level CNET l31-24 Peak Surge Voltage (V) 6000 6000 4000 6000 4000 1500 800 100 2500 1000 5000 4000 Voltage Waveform (s) 10/700 10/700 1.2/50 10/700 1.2/50 10/160 10/560 9/720 2/10 10/1000 2/10 0.5/700 Current Waveform (s) 5/310 5/310 1/20 5/310 8/20 10/160 10/560 5/320 2/10 10/1000 2/10 0.8/310 Admissible Ipp (A) 150 150 100 150 100 200 100 25 500 100 500 100 Necessary Resistor () -
BLOCK DIAGRAM
270
270
Pin 1 2 3/4/5 6/7/8 9 10 TAB
Symbol FS TIPS TIPL RINGL RINGS NC GND
Description Failure Status TIP (SLIC side) TIP (Line side) RING (Line side) RING (SLIC side) Not connected Ground
2/24
CLP270M
APPLICATION NOTE 1. INTRODUCTION This device includes a primary protection level and is suitable for main distribution frames and line cards. This protection concept is explained and, in addition, the CLP270M performances are analysed when Fig. 1: Subscriber line protection topology
"PRIMARY PROTECTION"
"SECONDARY PROTECTION"
Telecommunication line
CLP270M
MDF
SLIC
LINE CARD
EXCHANGE
"SECONDARY PROTECTION"
Telecommunication
CLP270M
line
MDF
THDTxx or LCP1511D or LCDP1511D LINE CARD
SLIC
EXCHANGE
facing different surges as described in the BELLCORE GR 1089 recommendations. Figure 1 is a simplified block diagram of a subscriber line protection that is commonly used. This shows two different topologies : A "primary protection" located on the Main Distribution Frame (MDF) eliminates coarsely the high energy environmental disturbances (lightning transients and AC power mains disturbances) A "secondary protection" located on the line card includes a primary protection level (first stage) and a residual protection (second stage) which eliminates finely the remaining transients that have not been totally suppressed by the first stage.
s s
2. STMicroelectronics CLP270M CONCEPT 2.1. Evolution of the SLIC protection Over the years, the silicon protection performances have considerably changed. The first generation of products like SMTHBTxx and SMTHDTxx offered fixed overvoltage protection against surges on either TIP or RING line in four Fig. 2: Line card protection packages. The following generation like THBTxx and Programmable I thanks to an THDTxx still offered fixed overvoltage protection Programmable external resistor against surges on both TIP and RING lines in two thanks to any +I SWON packages. external voltage reference The next step was the introduction of the LCP1511D which brought the advantage of full V programmable voltage. Today, the CLP270M combines the features of all -I SWON the previous generations. In addition to that, it offers an overcurrent detection when operating in Line card speech mode and also a Failure Status output operating signal. conditions
3/24
CLP270M
The figure 2 summarizes the firing modes of the CLP270M which basically hold the SLIC inside its correct Fig. 3 : CLP270M in line card
I Fuse TIP
Rsense
TIPL TIPS 1 -Vbat
Overcurrent detector
Rp
2 Overvoltage detector Over voltage reference (+/- 270 V) External voltage reference -Vbat
TIP
OR SW3 SW1
(*)
SLIC
FS SW4 SW2 OR Overvoltage detector Overvoltage reference (+/- 270 V)
GND
1
Rp
2
RING
Overcurrent detector Ring Generator
RINGL
RINGS
RING Fuse
Rsense
(*) LCP1511D or THDT series or LCDP1511D
voltage and current values. 2.2 Application circuit: CLP270M in line card. Figure 3 above shows the topology of a protected analog subscriber line at the exchange side. The CLP270M is connected to the ring relay via two balanced Rp resistors, and to the Subscriber Line Interface Circuit. A second device is located near the SLIC : it can be either a LCP1511D, a THDT series or a LCDP1511D. These two devices are complementary and their functions are explained below : The first stage based on CLP270M manages the high power issued from the external surges. When used in ringing mode, the CLP270M operates in voltage mode and provides a symmetrical and bidirectional overvoltage protection at +/- 270 V on both TIP and RING lines. When used in speech mode, the CLP270M operates in current mode and the activation current of the CLP270M is adjusted by Rsense. The second stage is the external voltage reference device which defines the firing threshold voltage during the speech mode and also assumes a residual power overvoltage suppression. This protection stage can be either a fixed or programmable breakover device. The THDTxx family acts as a fixed breakover device while the LCP1511D or the LCDP1511D operates as a programmable protection. Thanks to this topology, the surge current in the line is reduced after the CLP270M. Because the remaining surge energy is low, the power ratings of Rp, the ring relay contacts and the external voltage reference circuit can be downsized. This results in a significant cost reduction.
s s
4/24
CLP270M
Fig. 4: Switching by voltage during ringing mode.
Fuse TIP
ILG
Rsense
TIPL TIPS 1/2 CLP270M 1
ILG
A1
Rp
Overcurrent detector 2 Overvoltage detector Overvoltage reference (+/- 270 V)
2 1
-270 +270
VLG
V
OR SW3 SW1
3
FS GND
2.3. Ringing mode In ringing mode (Ring relay in position 2), the only protection device involved is the CLP270M. In normal conditions, the CLP270M operates in region 1 of A1 curve, and is idle. If an overvoltage occuring between TIP (or RING) and GND reaches the internal overvoltage reference (+/- 270 V), the CLP270M acts and the line is short-circuited to GND. At this time the operating point moves to region 2 for positive surges (region 3 for negative surges). Once the surge current falls below the switch off current ISWOFF, the device returns to its initial state (region 1). For surges occuring between TIP and RING, the CLP270M acts in the same way. This means that the CLP270M ensures a tripolar protection. When used alone, the CLP270M acts at the internal overvoltage reference level (+/- 270 V). Furthermore, it is possible to adjust this threshold level to a lower voltage by using: Fig. 5a: Method to adjust the reference voltage.
1 Fuse TIP
Rsense
TIPL TIPS
Rp
2 VZ1
Overcurrent detector
OR SW3 SW1
Overvoltage detector
Overvoltage reference (+/- 270 V)
VZ2
FS SW4 SW2 OR Overvoltage detector Overvoltage reference (+/- 270 V)
GND
VZ3
Overcurrent detector VZ4 RINGL RINGS 1
RING Fuse
Rsense
Rp
2
5/24
CLP270M
Fig. 5b: Method to adjust the reference voltage.
1 Fuse TIP
Rsense
TIPL TIPS
Rp
2
Overcurrent detector VB1 Overvoltage reference (+/- 270 V)
OR SW3 SW1
Overvoltage detector
FS SW4 SW2 OR Overvoltage detector Overvoltage reference (+/- 270 V)
GND
VB2 Overcurrent detector
RINGL
RINGS
1
RING Fuse
Rsense
Rp
2
Fig. 6: Switching by current during speech mode.
Fuse TIP
ILG
Rsense
TIPL TIPS 1
ILG A2
-Vbat
Rp
Overcurrent detector 2 Overvoltage detector Overvoltage reference (+/- 270 V)
5 4
OR SW3 SW1
VLG
External voltage reference
-VREF2
VREF1
6
VLG
FS
GND
s
s
up to 4 fixed external voltage reference (VZ1 to VZ4) (see fig. 5a, here-below). external reference supplies, Vb1 and Vb2 (see fig. 5b, on next page).
2.4. Speech mode In speech mode (Ring relay in position 1), the protection is provided by the combination of both CLP270M and the external voltage reference device. In normal conditions, the working point of this circuit is located in region 4 of A2 curve : the CLP270M is idle. When a surge occurs on the line, the external voltage reference device clamps at GND or -Vbat respectively for positive and negative surges. This generates a current which is detected by Rsense and causes the protection to act : the line is short-circuited to GND.
6/24
CLP270M
Fig. 7a and 7b: Switching-on current versus Rsense.
ISWON (T, Rsense) / ISWON (25C, 4 ) 2
@-20C @25C @75C
Iswon @ 25C (mA) 500 300 200
Iswon min Iswon max Iswon min Iswon max negative negative positive positive
1
0.5 0.3
100 50
0.2
3
3
5
7 Rsense ()
9
11
13
5 7 Rsense ()
9
11
The operating point moves to region 5 for positive surges or region 6 for negative surges. Once the surge current falls below the switching-off current ISWOFF, the CLP270M returns to its initial state (region 4). The choice of the switching-on currents is function of the Rsense resistors. In normal operating condition the current (typically below -100 mA) should not activate the protection device CLP270M. Therefore the level of activation is to be chosen just above this limit (-200 mA). This level is adjusted through Rsense. Figures 7a and 7b enable the designers to choose the right Rsense value. EXAMPLE : The choice of Rsense = 4 ensures a negative triggering of -190 mA min and -320 mA max. In this case, the positive triggering will be 150mA min and 280 mA max. 2.5. Failure Status The CLP270M has an internal feature that allows the user to get a Failure Status (FS) indication. When the CLP270M is short-circuiting the line to GND, a signal can be managed through pin 1. This signal can be used to turn a LED on in order to provide a surge indication. It may also be used with a logic circuitry to Fig. 8: Failure Status circuit and diagnostic.
Rsense 1 FAILURE CLP270M
1k
Fig. 9 : Operation limits and destruction zone of the CLP270M.
5 000 2 000 1 000 500 200 100 50 20
STATUS
Rsense +12V
10 0.01
0.02
0.05
0.1
0.2 t (ms)
0.5
1
2
5
10
count the number of disturbances appearing on the lines. If a surge exceeding the maximum ratings of the CLP270M occurs on the line, the device will fail in a short-circuit state.
7/24
CLP270M
The figure 9 shows two different curves : The lower one indicates the maximum guaranted working limits of the CLP270M.
s
Table 1: First level lightning surge. Surge Minimum peak voltage (volts) Minimum Maximum rise peak current / Minimum per conductor decay time for (Amps) voltage and current (s) 100 100 100 500 25 10/1000 10/360 10/1000 2/10 10/360 Repetitions, each polarity Test connections per table 4.1
1 2 3 4 5
+/- 600 +/- 1000 +/- 1000 +/- 2500 +/- 1000
25 25 25 10 5
A A A B B
Table 2: Second level lightning surge. Surge Minimum peak voltage (volts) Minimum Maximum rise peak current / Minimum per conductor decay time for (Amps) voltage and current (s) 500 2/10 Repetitions, each polarity Test connections per table 4.1
1
+/- 5000
1
B
The upper curve shows the limit above which the CLP270M is completely destructed . In this case, the Fail Diagnostic pin is on. 3. CLP270M TEST RESULTS ACCORDING TO BELLCORE 1089 REQUIREMENTS.
s
8/24
CLP270M
Table 3: First level AC power fault (table 4-7 of GR-1089-CORE issue 2, december 1997). Test Voltage (VRMS) Short circuit current per conductor (Amps) 0.33 0.17 1 (at 600V) Duration Primary protection Test connections per table 4.1 A A A
1 2 3
50 100 200, 400 and 600 1000
15 minutes 15 minutes 60 1 s application of each voltage 60 1s applications 60 5s applications 30s 2s 1s 0.5s
Removed Removed Removed
4
1
Operative protector in place Removed Removed Removed Removed Operative protector in place
B
5 6 7 8 9
see figure 4-3 600 600 600 1000
see figure 4-3 0.5 2.2 3 5
see figure 4-3 A A A B
Table 4: Second level AC power fault (table 4-8 of GR-1089-CORE issue 2, december 1997). Test Test for Voltage (VRMS) Short circuit current per conductor (Amps) 25 60 7 2.2 (at 600 V) Duration Test connections per table 4.1 A A A A
1 2 3 4 5
Secondary contact Primary contact Short-term fault induction Long-term fault induction High impedance induction
120, 277 600 600 100-600
15 minutes 5 seconds 5 seconds 15 minutes 15 minutes
9/24
CLP270M
Table 5: Test connection (table 4-1 of GR-1089-CORE). Test A Two-wire interface 1. Tip to generator, Ring to ground 2. Ring to generator, Tip to ground 3. Tip to generator, Ring to generator simultaneously B Tip to generator, Ring to generator simultaneously Four-wire interface 1. Each lead (T, R, T1, R1) to generator with other three leads grounded 2. Tip and Ring to generator simultaneously, T1 and R1 to ground 3. T1 and R1 to generator simultaneously, Tip and Ring to ground T, R, T1, R1 to generator simultaneously
S1 Switch unit under test
Limiting resistance (IF specified)
T E R M
S2 S3
Voltage Source
S4
T E R M
Test
Table 6: Application of lightning and AC power fault test voltages (table 4-2 of GR-1089-CORE). Test T to generator, R to ground (condition A1 of table 4-1) R to generator, T to ground (condition A2 of table 4-1) T to generator, R to generator simultaneously (condition A3 of table 4-1) S1 Closed Open Closed S2 Open Closed Open S3 Open Closed Closed S4 Closed Open Open
3.1. BELLCORE GR-1089-CORE requirements: Tables 1 and 2 summarize the lighting surges required by the bellcore 1089.
10/24
CLP270M
Tables 1 to 6 summarize the surge needs defined by Bellcore regarding both lightning and AC power fault. In case of first level test, the equipment under test shall be operating after the surge. For the second level tests, the equipment under test may be damaged, but no fire or electrical safety hazard may occur. 3.2. First level lightning surge:
3.2.1. ringing mode Fig. 10: Lightning simulation test.
I1 2/10 s GENERATOR +/- 2.5 kV (500 A) TIPL 1/2 CLP270M GND 4
Rsense
TIPS V1
Rp
Lightning phenomena are the most common surge causes. The purpose of this test is to check the behavior of the CLP270M against these lightning strikes. Fig. 11: CLP270M response to a positive surge. Fig. 12 : CLP270M response to a negative surge.
Figures 11 and 12 show that the remaining overvoltage does not exceed +/- 500 V. The CLP270M Fig. 13: Lightning test in speech mode.
I1 2/10 s GENERATOR +/- 5 kV (500 A) TIPL 1/2 CLP270M GND 4 50 Rp TIPS I2 SLIC
Rsense
-48V
V1 LCP1511D
V2
11/24
CLP270M
Fig. 14: CLP270M response to a positive surge. Fig. 15: CLP270M reponse to a negative surge.
switches on within 250ns and withstands the 500A given by the BELLCORE 2/10s generator. 3.2.2. Speech mode Figures 14 and 15 give the voltage and current behavior during positive and negative 2.5kV, 2/10s, 500A surge tests using a LCP1511D as second stage protection device. The firing threshold values are now adjusted to GND and to -Vbat (-48V) by the action of the second stage protection which acts as an external voltage reference.
12/24
CLP270M
As shown on these figures, the maximum remaining voltage does not exceed +8.5V for positive surges and -65V for negative surges. Fig. 16: Lightning test in Ringing mode.
I1 2/10 s GENERATOR +/- 5 kV (500 A) TIPL
4
Rsense
TIPS V1
Rp
1/2 CLP270M GND
Fig. 17: CLP270M response to a positive surge.
Fig. 18: CLP270M response to a negative surge.
3.3. Second level lightning surge 3.3.1. Lightning test in ringing mode
13/24
CLP270M
The figures 17 and 18 give the voltage and current behavior during positive and negative 5kV, 2/10s,500A surge with the CLP270M acting in Ringing mode. Fig. 19: Lightning test in Speech mode.
I1 2/10 s GENERATOR +/- 5 kV (500 A) TIPL
4
Rsense
TIPS
50 Rp
I2 SLIC
1/2 CLP270M GND
-48V
V1 LCP1511D
V2
Fig. 20: CLP270M response to a positive surge.
Fig. 21: CLP270M response to a negative surge.
3.3.2. Speech mode The figures 20 and 22 give the voltage and current behavior during positive and negative 5kV, 2/10s,500A surge with the CLP270M acting in speech mode.
14/24
CLP270M
The CLP270M withstands the second level lightning surge test without trouble. 3.4. FIRST AND SECOND LEVEL AC POWER FAULT
Fig. 22: AC power fault test in Ringing mode.
Fig. 23: Example of behavior when facing test 3 (400V, 600).
I1 4
Rs
Rsense
TIPL TIPS 1/2 CLP270M GND V1
Rp
V(RMS) 50Hz
Fig. 24: AC power fault test in Speech mode.
Fig. 25: Example of behavior when facing test 3 (400V, 600).
I1
4
Rs
TIPL V(RMS) 50 Hz
Rsense
50 Rp
SLIC
TIPS -48V LCP1511D V2
1/2 CLP270M GND
3.4.1. Ringing mode
The figures 23 and 25 give the voltage and current at the CLP270M terminals in Ringing mode and Speech mode. The CLP270M is able to withstand all the first level AC power fault tests as required in the table 4-7 of GR-1089-CORE standard. For the second level AC power fault tests serial protection as PTC or fuse are needed. All these curves, lightning and AC power fault represent the behavior of the CLP270M in worst case tests, any how the CLP270M withstands all the others surges of the Bellcore GR1098 standard. For the second level AC power fault test, the use of series protection elements (PTC or fuses) are needed.
15/24
CLP270M
ABSOLUTE MAXIMUM RATINGS (RSENSE = 4 , and Tamb = 25 C) Symbol IPP Parameter Line to GND peak surge current Test Conditions 10/1000s (open circuit voltage wave shape 10/1000s) 5/310s (open circuit voltage wave shape 10/700s) 2/10s (open circuit voltage wave shape) ITSM Non repetitive surge peak on-state current (TIP or RING versus Ground) F = 50 Hz Tstg Tj TL Storage temperature range Maximum junction temperature Maximum lead temperature for soldering during 10 s tp = 20 ms tp = 200 ms tp = 2 s Value 100 150 500 60 30 15 - 40 to + 150 150 260 A A A C C Unit A
ELECTRICAL CHARACTERISTICS (RSENSE = 4 , and Tamb = 25C) Symbol ILGL Parameter Line to GND leakage current Overvoltage internal reference Line to GND voltage at SW1 or SW2 switching-on Line to GND current at SW1 or SW2 switching-off (negative current) Line current at SW1 or SW2 switching-on RING to GND capacitance TIP to GND capacitance TIP to RING capacitance Test Conditions . VLG = 240 V . Measured between TIP (or RING) and GND . ILG = 1 mA . Measured between TIP (or RING) and GND . Measured at 50 Hz between TIPL (or RINGL) and GND . Refer to test circuit page 17 150 265 Value Min. Typ. Max. 10 Unit A
Vref
V
VSWON ISWOFF
400
V mA
ISWON C
. Positive pulse . Negative pulse . VRINGL = -1 V . VTIPL = -48 V . VGND = 0 V . F = 1 MHz VRMS = 1V
150 190 180 62 57
280 320
mA pF
16/24
CLP270M
TEST CIRCUIT FOR ISWOFF PARAMETER : GO-NO GO TEST
R - VP D.U.T. VBAT = - 48 V Surge generator
This is a GO-NO GO test which allows to confirm the switch-off (ISWOFF) level in a functional test circuit. TEST PROCEDURE : - Adjust the current level at the ISWOFF value by short circuiting the D.U.T. - Fire the D.U.T. with a surge current : IPP = 10A, 10/1000s. - The D.U.T. will come back to the OFF-state within a duration of 50ms max. Fig. 26: Typical relative variation of switching-on current (positive or negative) versus RSENSE resistor and junction temperature (see test condition Fig. 28).
ISWON (T, Rsense) / ISWON (25C, 4 ) 2
@-20C @25C @75C
Fig. 27: Variation of switching-on current versus RSENSE at 25C.
Iswon @ 25C (mA) 500 300 200
Iswon min Iswon max Iswon min Iswon max negative negative positive positive
1
0.5 0.3 0.2
100 50
3 5 7 Rsense () 9 11 13
3
5 7 Rsense ()
9
11
Fig. 28: ISWON MEASUREMENT - Iswon = I1 when the CLP270M switches on (I1 is progressively increased using R) - Both TIP and RING sides of the CLP270M are checked - RL = 10 .
R sense RL I1
Fig. 29: Relative variation of switching-off current versus junction temperature for RSENSE between 3 and 10 .
ISWOFF [TjC] / ISWOFF [25C] 2.0 1.8 1.6 1.4 1.2 1.0 0.8 0.6 0.4 -40
48 V
TIPL
TIPS R
DUT
GND
RINGL RINGS
-20
0
20 40 Tj (C)
60
80
17/24
CLP270M
Fig. 30: Relative variation of switching-off current versus RSENSE (between 3 and 10 ).
ISWOFF [Rsense] / ISWOFF [4 ] 1.6 1.4 1.2 1.0 0.8 0.6 0.4 4 6 8 Rsense () 10
Fig. 31: Residual current l1 after the CLP270M. The residual current l1 is defined by its peak value (IP) and its duration () @ IP/2 (see below circuit test). Current surge input waveform(s) IPP(A) 5/310 positive surge 130A negative surge Residual current after the CLP270M Peak cur- waveform t(s) rent IP (A) 4.2 1.1 1 0.5
-48V
R sense R = 50 Ohms
SURGE GENERATOR
TIPL
TIPS GND RINGS
I1
DUT
RINGL
Fig. 32: Relative variation of switching-on voltage versus dV/dt with an external resistor of 4 .
Vswon/Vref
1.2 1.15 1.1 1.05 1 0.95
Fig. 33: Relative variation of internal reference voltage versus junction temperature (ILG=1mA).
VREF [TjC] / V REF [25C]
1.10 1.05
1.00 0.95 0.90
5 10 20 50 100 200 500 1,000
0.85 -40
-20
0
20
40
60
dV/dt(V/us)
Tj (C)
18/24
CLP270M
Fig. 34: Typical junction capacitance (TIPL/GND) versus applied voltage.
C (pF) 220 200 180 160 140 120 100 80 60 40
Fig. 35: Maximum non repetitive surge RMS on state current versus overload duration .
ITSM(A) 100 90 80 70 60
TIP or RING vs GND F=50Hz Tj initial=25C
50
40 30 20 10
0
10
20
30 VR (V)
40
50
60
0 0.01
0.1
1
t(s)
10
100
1000
19/24
CLP270M
SOLDERING RECOMMENDATION The soldering process causes considerable thermal stress to a semiconductor component. This has to be minimized to assure a reliable and extended lifetime of the device. The PowerSO-10TM package can be exposed to a maximum temperature of 260C for 10 seconds. However a proper soldering of the package could be done at 215C for 3 seconds. Any solder temperature profile should be within these limits. As reflow techniques are most common in surface mounting, typical heating profiles are given in Figure 36, either for mounting on FR4 or on metal-backed boards. For each particular board, the appropriate heat profile has to be adjusted experimentally. The present proposal is just a starting point. In any case, the following precautions have to be considered : - always preheat the device - peak temperature should be at least 30 C higher than the melting point of the solder alloy chosen - thermal capacity of the base substrate Fig 36 : Typical reflow soldering heat profile Voids pose a difficult reliability problem for large surface mount devices. Such voids under the package result in poor thermal contact and the high thermal resistance leads to component failures. The PowerSO-10 is designed from scratch to be solely a surface mount package, hence symmetry in the x- and y-axis gives the package excellent weight balance. Moreover, the PowerSO-10 offers the unique possibility to control easily the flatness and quality of the soldering process. Both the top and the bottom soldered edges of the package are accessible for visual inspection (soldering meniscus). Coplanarity between the substrate and the package can be easily verified. The quality of the solder joints is very important for two reasons : (I) poor quality solder joints result directly in poor reliability and (II) solder thickness affects the thermal resistance significantly. Thus a tight control of this parameter results in thermally efficient and reliable solder joints.
Temperature (o C)
250
245 oC 215oC
200
Epoxy FR4 board
Soldering
150
Preheating
Cooling
100
Metal-backed board
50
0 0 40 80 120 160 200 240 280 320 360
Time (s)
20/24
CLP270M
SUBSTRATES AND MOUNTING INFORMATION The use of epoxy FR4 boards is quite common for surface mounting techniques, however, their poor thermal conduction compromises the otherwise outstanding thermal performance of the PowerSO-10. Some methods to overcome this limitation are discussed below. One possibility to improve the thermal conduction is the use of large heat spreader areas at the copper layer of the PC board. This leads to a reduction of thermal resistance to 35 C for 6 cm2 of the board heatsink (see fig. 37). Use of copper-filled through holes on conventional FR4 techniques will increase the metallization and decrease thermal resistance accordingly. Using a configuration with 16 holes under the spreader of the package with a pitch of 1.8 mm and a diameter of 0.7 mm, the thermal resistance (junction heatsink) can be reduced to 12C/W (see fig. 38). Beside the thermal advantage, this solution allows multi-layer boards to be used. However, a drawback of this traditional material prevent its use in very high power, high current circuits. For instance, it is not advisable to surface mount devices with currents greater than 10 A on FR4 boards. A Power Mosfet or Schottky diode in a surface mount power package can handle up to around 50 A if better substrates are used.
Fig 37 : Mounting on epoxy FR4 head dissipation by extending the area of the copper layer
Copper foil
FR4 board
Fig 38 : Mounting on epoxy FR4 by using copper-filled through holes for heat transfer
Copper foil
FR4 board
heatsink
heat transfer
21/24
CLP270M
A new technology available today is IMS - an Insulated Metallic Substrate. This offers greatly enhanced thermal characteristics for surface mount components. IMS is a substrate consisting of three different layers, (I) the base material which is available as an aluminium or a copper plate, (II) a thermal conductive dielectrical layer and (III) a copper foil, which can be etched as a circuit layer. Using this material a thermal resistance of 8C/W with 40 cm2 of board floating in air is achievable (see fig. 39). If even higher power is to be Fig 39 : Mounting on metal backed board dissipated an external heatsink could be applied which leads to an Rth(j-a) of 3.5C/W (see Fig. 40), assuming that Rth (heatsink-air) is equal to Rth (junction-heatsink). This is commonly applied in practice, leading to reasonable heatsink dimensions. Often power devices are defined by considering the maximum junction temperature of the device. In practice , however, this is far from being exploited. A summary of various power management capabilities is made in table 1 based on a reasonable delta T of 70C junction to air. Fig 40 : Mounting on metal backed board with an external heatsink applied
Copper foil
FR4 board
Copper foil Insulation
Aluminium
Aluminium heatsink
The PowerSO-10 concept also represents an attractive alternative to C.O.B. techniques. PowerSO-10 offers devices fully tested at low and high temperature. Mounting is simple - only conventional SMT is required - enabling the users to get rid of bond wire problems and the problem to
control the high temperature soft soldering as well. An optimized thermal management is guaranteed through PowerSO-10 as the power chips must in any case be mounted on heat spreaders before being mounted onto the substrate.
TABLE 7 : THERMAL IMPEDANCE VERSUS SUBSTRATE PowerSo-10 package mounted on 1.FR4 using the recommended pad-layout 2.FR4 with heatsink on board (6cm2) 3.FR4 with copper-filled through holes and external heatsink applied 4. IMS floating in air (40 cm2) 5. IMS with external heatsink applied (*) Based on a delta T of 70 C junction to air. Rth (j-a) 50 C/W 35 C/W 12 C/W 8 C/W 3.5 C/W P Diss (*) 1.5 W 2.0 W 5.8 W 8.8 W 20 W
22/24
CLP270M
PACKAGE MECHANICAL DATA
B
0.10 A B
10 H E
6 E2 E3 E1
1
5
SEATING PLANE
e
0.25 M
B
DETAIL "A"
A C
h
D D1
Q
A F A1
SEATING PLANE
A1 L
DETAIL "A"
E4
a
DIMENSIONS REF. A A1 B C D D1 E E1 E2 Millimeters Min. Typ. Max. 3.35 0.00 0.40 0.35 9.40 7.40 9.30 7.20 7.20 0.10 Min. 0.00 3.65 0.131 0.60 0.0157 0.55 0.0137 9.60 0.370 7.60 0.291 9.50 0.366 7.40 0.283 7.60 0.283 Inches Typ. Max. 0.143 0.0039 0.0236 0.0217 0.378 0.299 0.374 0.291 0.299 h L Q 1.20 1.70 REF. E3 E4 e F H 1.25 13.8 0 0.50
DIMENSIONS Millimeters Min. Typ. Max. 6.10 5.90 1.27 1.35 0.0492 14.4 0.543 0 0.019 1.80 0.0472 0.067 0.0708 Min. 6.35 0.240 6.10 0.232 0.05 0.0531 0.567 Inches Typ. Max. 0.250 0.240
MARKING Package PowerSO-10
TM
Type CLP270M
Marking CLP270M
Packing Tube Tape and reel
Base Quantity 50 60
23/24
CLP270M
ORDER CODE CLP Current Limiting Protection 270 M - TR TR = tape and reel = tube Package : PowerSO-10
Minimum operation voltage
FOOT PRINT MOUNTING PAD LAYOUT RECOMMENDED
0.54 - 0.60
HEADER SHAPE
Dimensions in millimeters SHIPPING TUBE
Information furnished is believed to be accurate and reliable. However, STMicroelectronics assumes no responsibility for the consequences of use of such information nor for any infringement of patents or other rights of third parties which may result from its use. No license is granted by implication or otherwise under any patent or patent rights of STMicroelectronics. Specifications mentioned in this publication are subject to change without notice. This publication supersedes and replaces all information previously supplied. STMicroelectronics products are not authorized for use as critical components in life support devices or systems without express written approval of STMicroelectronics.
24/24
14.6 - 14.9 1.27 0.67 - 0.73 9.5
10.8 - 11.0
6.30
Dimensions in millimeters
C B
A B C Length tube
DIMENSIONS (mm) TYP 18 12 0,8 532
A
The ST logo is a registered trademark of STMicroelectronics (c) 2003 STMicroelectronics - Printed in Italy - All rights reserved. STMicroelectronics GROUP OF COMPANIES Australia - Brazil - Canada - China - Finland - France - Germany Hong Kong - India - Israel - Italy - Japan - Malaysia - Malta - Morocco - Singapore Spain - Sweden - Switzerland - United Kingdom - United States. http://www.st.com


▲Up To Search▲   

 
Price & Availability of CLP270M-TR

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X